Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 407
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38641438

RESUMO

BACKGROUND: Candidates for transcatheter aortic valve replacement (TAVR) occasionally have a "borderline-size" aortic annulus between 2 transcatheter heart valve sizes, based on the manufacturer's sizing chart. Data on TAVR outcomes in such patients are limited. METHODS: We retrospectively reviewed 1816 patients who underwent transfemoral-TAVR with balloon-expandable valve (BEV) at our institution between 2016 and 2020. We divided patients into borderline and non-borderline groups based on computed tomography-derived annular measurements and compared outcomes. Furthermore, we analyzed procedural characteristics and compared outcomes between the smaller- and larger-valve strategies in patients with borderline-size annulus. RESULTS: During a median follow-up of 23.3 months, there was no significant difference between the borderline (n = 310, 17.0 %) and non-borderline (n = 1506) groups in mortality (17.3 % vs. 19.5 %; hazard ratio [HR] = 0.86 [95% CI = 0.62-1.20], p = 0.39), major adverse cardiac/cerebrovascular events (MACCE: death/myocardial infarction/stroke, 21.2 % vs. 21.5 %; HR = 0.97 [0.71-1.32], p = 0.85), paravalvular leak (PVL: mild 21.8 % vs. 20.6 %, p = 0.81; moderate 0 % vs. 1.2 %; p = 0.37), or mean gradient (12.9 ± 5.8 vs. 12.6 ± 5.2 mmHg, p = 0.69) at 1 year. There was no significant difference between the larger-(n = 113) and smaller-valve(n = 197) subgroups in mortality (23.7 % vs. 15.2 %; HR = 1.57 [0.89-2.77], p = 0.12), MACCE (28.1 % vs. 18.4 %; HR = 1.52 [0.91-2.54], p = 0.11), mild PVL (13.3 % vs. 25.9 %; p = 0.12), or mean gradient (12.3 ± 4.5 vs. 13.6 ± 5.3 mmHg, p = 0.16); however, the rate of permanent pacemaker implantation (PPI) was higher in the larger-valve subgroup (15.9 % vs. 2.6 %, p < 0.001). CONCLUSION: Borderline-size annulus is not associated with higher risk of adverse outcomes after BEV-TAVR. However, the larger-valve strategy for borderline-size annulus is associated with higher PPI risk, suggesting a greater risk of injury to the conduction system.

2.
Am J Cardiol ; 217: 86-93, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38432333

RESUMO

Low muscle mass (LMM) is associated with worse outcomes in various clinical situations. Traditional frailty markers have been used for preoperative risk stratification in patients who underwent transcatheter aortic valve replacement (TAVR). However, preoperative imaging provides an opportunity to directly quantify skeletal muscle mass to identify patients at higher risk of procedural complications. We reviewed all TAVR recipients from January to December 2018 and included subjects with preprocedural chest computed tomography. Multi-slice automated measurements of skeletal muscle mass were made from the ninth to twelfth thoracic vertebrae and normalized by height squared to obtain skeletal muscle index (cm2/m2). LMM was defined as the lowest gender-stratified skeletal muscle index tertile. Strength testing was collected during pre-TAVR evaluation. Primary outcome was a composite of perioperative complications, 1-year rehospitalization, or 1-year mortality. In our cohort, 238 patients met inclusion criteria, and 80 (33.6%) were identified to have LMM. Patients with LMM were older with lower body mass index, decreased grip strength, lower hemoglobin A1c, and higher N-terminal pro-brain natriuretic peptide. They had greater rates of the composite outcome and 2-year all-cause mortality, which remained significant on multivariable adjustment (hazard ratio 1.71, 95% confidence interval 1.05 to 2.78, p = 0.030 and hazard ratio 2.31, 95% confidence interval 1.02 to 5.24, p = 0.045, respectively) compared with patients without LMM; there was no significant difference in 5-year all-cause mortality. In conclusion, LMM was associated with an increase in the primary composite outcome and 2-year all-cause mortality in TAVR recipients. Using automatic muscle processing software on pre-TAVR computed tomography scans may serve as an additional preoperative risk stratification tool.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Tomografia Computadorizada por Raios X/métodos , Músculo Esquelético/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco
4.
JACC Case Rep ; 29(4): 102199, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38379657

RESUMO

Transcatheter aortic valve replacement is not widely used in patients with congenital heart disease. We describe our single-center experience of transcatheter aortic valve replacement in congenital heart disease, demonstrating short-term feasibility and safety, role in lifetime management of congenital aortic valve disease, and use as a bridge to recovery, future surgery, or transplantation.

5.
Open Heart ; 11(1)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38290731

RESUMO

BACKGROUND: Patients who experience in-hospital ST-segment elevation myocardial infarction (iSTEMI) represent a uniquely high-risk cohort owing to delays in diagnosis, prolonged time to reperfusion and increased mortality. Quality initiatives aimed at improving the care of this vulnerable, yet understudied population are needed. METHODS: This study included consecutive patients with iSTEMI treated with percutaneous coronary intervention (PCI) between 1 January 2011 and 15 July 2019 at a single, tertiary referral centre. A comprehensive iSTEMI protocol (CSP) was implemented on 15 July 2014, incorporating: (1) cardiology fellow activation of the catheterisation lab using standardised criteria, (2) nursing chest pain protocol, (3) improved electronic access to electrocardiographic studies, (4) checklist for initial triage and management, (5) 24/7/365 catheterisation lab readiness and (6) radial-first PCI approach. Key metrics and clinical outcomes were compared before and after CSP implementation. RESULTS: Among 125 total subjects, the post-CSP cohort (n=81) was younger, had more males and were more likely to be hospitalised for cardiac-related reasons relative to the pre-CSP cohort (n=44) who were more likely hospitalised for operative-related aetiologies. After CSP adoption, median ECG-to-first-device-activation time decreased from 113 min to 64 min (p<0.001), goal ECG-to-first-device-activation time increased from 36% to 76% of patients (p<0.001), administration of guideline-directed medical therapy prior to PCI increased from 27.3% to 65.4% (p<0.001), trans-radial access increased from 16% to 70% (p<0.001) and rates of discharge home increased from 56.8% to 76.5% (p=0.04). Statistically insignificant numerical reductions were observed post-CSP in in-hospital mortality (18.2% vs 9.9%, p=0.30), 30-day mortality (15.9% vs 12.3%, p=0.78) and 1-year mortality (27.3% vs 21.0%, p=0.57). CONCLUSIONS: The implementation of a CSP was associated with marked enhancements in key care metrics among patients with iSTEMI. Among a larger cohort, the use of a CSP yielded a significant reduction in ECG-to-first-device-activation time in a particularly vulnerable population at high risk of death.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Masculino , Estudos de Coortes , Hospitais , Estudos Observacionais como Assunto , Intervenção Coronária Percutânea/efeitos adversos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Triagem , Feminino
6.
Eur Heart J ; 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38270189

RESUMO

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.

7.
Struct Heart ; 8(1): 100227, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283572

RESUMO

Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve replacement being increasingly considered in younger patients with symptomatic BAV, with good clinical results, yet without randomized trial evidence. Procedural technique, along with clinical outcomes, have considerably improved in BAV patients compared with tricuspid aortic stenosis patients undergoing transcatheter aortic valve replacement. The present review summarizes the novel BAV classification systems and examines contemporary surgical and transcatheter approaches.

8.
JACC Cardiovasc Interv ; 17(1): 60-72, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38069986

RESUMO

BACKGROUND: Several orthotopic transcatheter strategies have been developed to treat severe tricuspid regurgitation (TR); however, many patients are deemed unsuitable. Caval valve implantation with the TricValve system addresses this unmet need. OBJECTIVES: This study sought to determine the impact of TricValve on systemic congestion and quality of life (QOL) at 1 year. METHODS: The TRICUS (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) and TRICUS EURO studies were prospective, nonblinded, nonrandomized, single-arm trials representing the early-in-man experience of the TricValve system in NYHA functional class III or IV severe TR patients, optimally medicated and ineligible for open heart surgery, with significant caval backflow. The primary endpoint was QOL metrics and functional status. The 1-year results of the combined cohort are described here. RESULTS: Forty-four patients were included. Mean age was 76.2 ± 7.5 years, 81.0% were women, and the TRISCORE (risk score model for isolated tricuspid valve surgery) was 5.3 ± 1.3. Clinical improvement at 1 year was achieved in 42 (95.5%) patients, measured by (at least 1 of) an increase in ≥15 points from baseline in 12-item Kansas City Cardiomyopathy Questionnaire score, improvement to NYHA functional class to I or II, or an increase ≥40 m in the 6-minute walk test. There were 3 (6.8%) deaths at 1-year follow-up (1 cardiovascular), and the heart failure rehospitalization rate was 29.5%. Stent fracture, conduction system disturbances, or clinically significant leaflet thrombosis were not detected. Abolished hepatic vein backflow was achieved and persisted in 63.8% of the patients, contributing towards a reduction in congestive symptoms, N-terminal pro-B-type natriuretic peptide levels (P = 0.032), and diuretic treatment. CONCLUSIONS: Caval valve implantation with the TricValve system associated with meaningful 1-year clinical improvements in terms of QOL along with relatively low mortality rates. (TRICUS Study - Safety and Efficacy of the TricValve® Device; NCT03723239).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Cateterismo Cardíaco , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
9.
Curr Opin Cardiol ; 39(2): 110-118, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38116802

RESUMO

PURPOSE OF REVIEW: The unique pathophysiologic considerations of severe tricuspid regurgitation (TR) have led to advancements in surgical and transcatheter treatments. The purpose of this review is to highlight the current surgical and transcatheter tricuspid valve interventions (TTVI) to functional TR. RECENT FINDINGS: Surgical repair with ring annuloplasty consistently demonstrates better outcomes than surgical replacement or other repair approaches. However, surgical uptake of TR correction remains relatively low, and operative mortality rates are still high owing to multiple comorbidities and advanced tricuspid valve disease/right ventricular dysfunction at time of referral. Pivotal trials for tricuspid transcatheter edge-to-edge repair (T-TEER) and transcatheter TV replacement (TTVR) indicate improved quality of life compared to medical therapy alone for high-surgical-risk patients with severe symptomatic TR. Trials are underway to assess caval valve implantation (CAVI), which holds hope for many severe TR patients who are not ideal candidates for T-TEER or orthotopic TTVR. Peri-procedural optimization of right ventricular function remains critical to promote both device success and patient outcomes. SUMMARY: Clinical outcomes after surgical TV intervention are poor, often due to intervening late in the disease course of TR. TTVI covers a treatment gap for patients deemed inoperable or high-surgical-risk, but earlier referral for TV interventions is still important prior to patients developing multiorgan dysfunction from chronic untreated TR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Fatores de Tempo , Cateterismo Cardíaco , Insuficiência Cardíaca/cirurgia
11.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38132642

RESUMO

BACKGROUND: Regional functional left ventricular (LV) assessment using current imaging techniques remains limited. Inward displacement (InD) has been developed as a novel technique to assess regional LV function via measurement of the regional displacement of the LV endocardial border across each of the 17 LV segments. Currently, normal ranges for InD are not available for clinical use. The aim of this study was to validate the normal reference limits of InD in healthy adults across all LV segments. METHODS: InD was analyzed in 120 healthy subjects with a normal LV ejection fraction, using the three standard long-axis views obtained during cardiac MRI that quantified the degree of inward endocardial wall motion towards the true LV center of contraction. For all LV segments, InD was measured in mm and expressed as a percentage of the theoretical degree of maximal segment contraction towards the true LV centerline. The arithmetic average InD was obtained for each of the 17 segments. The LV was divided into three regions, obtaining average InD at the LV base (segments 1-6), mid-cavity (segments 7-12) and apex (segments 13-17). RESULTS: Average InD was 33.4 ± 4.3%. InD was higher in basal and mid-cavity LV segments (32.8 ± 4.1% and 38.1 ± 5.8%) compared to apical LV segments (28.6 ± 7.7%). Interobserver variability correlations for InD were strong (R = 0.80, p < 0.0001). CONCLUSIONS: We provide clinically meaningful reference ranges for InD in subjects with normal LV function, which will emerge as an important screening and assessment imaging tool for a range of HFrEF therapies.

12.
Eur Heart J Open ; 3(6): oead127, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38105920

RESUMO

Aims: Conduction abnormalities necessitating permanent pacemaker (PPM) implantation remain the most frequent complication post-transcatheter aortic valve implantation (TAVI), yet reliance on PPM function varies. We evaluated the association of right-ventricular (RV)-stimulation rate post-TAVI with 1-year major adverse cardiovascular events (MACE) (all-cause mortality and heart failure hospitalization). Methods and results: This retrospective cohort study of patients undergoing TAVI in two high-volume centers included patients with existing PPM pre-TAVI or new PPM post-TAVI. There was a bimodal distribution of RV-stimulation rates stratifying patients into two groups of either low [≤10%: 1.0 (0.0, 3.6)] or high [>10%: 96.0 (54.0, 99.9)] RV-stimulation rate post-TAVI. Hazard ratios (HR) and 95% confidence intervals (CI) were calculated comparing MACE in patients with high vs. low RV-stimulation rates post-TAVI. Of 4659 patients, 408 patients (8.6%) had an existing PPM pre-TAVI and 361 patients (7.7%) underwent PPM implantation post-TAVI. Mean age was 82.3 ± 8.1 years, 39% were women. A high RV-stimulation rate (>10%) development post-TAVI is associated with a two-fold increased risk for MACE [1.97 (1.20, 3.25), P = 0.008]. Valve implantation depth was an independent predictor of high RV-stimulation rate [odds ratio (95% CI): 1.58 (1.21, 2.06), P=<0.001] and itself associated with MACE [1.27 (1.00, 1.59), P = 0.047]. Conclusion: Greater RV-stimulation rates post-TAVI correlate with increased 1-year MACE in patients with new PPM post-TAVI or in those with existing PPM but low RV-stimulation rates pre-TAVI. A shallower valve implantation depth reduces the risk of greater RV-stimulation rates post-TAVI, correlating with improved patient outcomes. These data highlight the importance of a meticulous implant technique even in TAVI recipients with pre-existing PPMs.

13.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37988439

RESUMO

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Desenho de Prótese
14.
JACC Case Rep ; 23: 102007, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37954951

RESUMO

Patients with severe tricuspid regurgitation and right ventricular dysfunction have limited therapeutic options due to anatomic complexity, advanced disease at presentation, and comorbidities. Caval valve implantation is an emerging transcatheter therapy. We present a case series of contrast-sparing caval valve implantation using intravascular ultrasound guidance in patients with renal failure. (Level of Difficulty: Advanced.).

16.
EuroIntervention ; 19(7): 549-570, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37720969

RESUMO

Stroke remains a devastating complication of transcatheter aortic valve replacement (TAVR), with the incidence of clinically apparent stroke seemingly fixed at around 3% despite TAVR's significant evolution during the past decade. Embolic showers of debris (calcium, atheroma, valve material, foreign material) are captured in the majority of patients who have TAVR using a filter-based cerebral embolic protection device (CEPD). Additionally, in systematic brain imaging studies, the majority of patients receiving TAVR exhibit new cerebral lesions. Mechanistic studies have shown reductions in the volume of new cerebral lesions using CEPDs, yet the first randomised trial powered for periprocedural stroke within 72 hours of a transfemoral TAVR failed to meet its primary endpoint of showing superiority of the SENTINEL CEPD. The present review summarises the clinicopathological rationale for the development of CEPDs, the evidence behind these devices to date and the emerging recognition of cerebral embolisation in many non-TAVR transcatheter procedures. Given the uniqueness of each of the various CEPDs under development, specific trials tailored to their designs will need to be undertaken to broaden the CEPD field, in addition to evaluating the role of CEPD in non-TAVR transcatheter heart interventions. Importantly, the cost-effectiveness of these devices will require assessment to broaden the adoption of CEPDs globally.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Embolia Intracraniana , Humanos , Coração , Encéfalo , Cálcio , Cateteres , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle
17.
Am J Cardiol ; 207: 39-47, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37722200

RESUMO

As mitral valve transcatheter edge-to-edge repair (M-TEER) is evolving as an effective treatment for high-risk surgical patients with mitral regurgitation, there is a pressing need for cardiologists to optimize resources through risk stratification of in-hospital mortality for this patient population. Although current risk-prediction models have been shown to predict adverse outcomes with reasonable accuracy, models trained using the US nationwide population are lacking. This study aimed to identify clinical, demographic, and procedural features that predict in-hospital mortality, and to derive and validate an in-hospital mortality risk-prediction tool in patients who have undergone M-TEER. A total of 9,373 admissions from the Nationwide Readmissions Database of patients who underwent M-TEER between 2015 and 2018 were used to develop and validate the model. We first performed least absolute shrinkage and selection operator (LASSO) regularization of Cox regression (Coxnet) that is 10-fold cross-validated. The non-zero coefficients were multiplied with the respective values of each observation of the predictors to build the scoring formula. Out of 9,373 admissions, 196 patients (2%) died in-hospital during index admission. In descending order, the top variables that were most predictive of in-hospital mortality were higher age, presence of fluid and electrolyte disturbance, and large metropolitan location of the hospital. The validation C-statistic of the MitraCox score was 0.82. Using X-tile software (Yale School of Medicine, New Haven, Connecticut), 2 cutoffs of the score were determined on the basis of in-hospital mortality and length of stay, and the survival of the population was classified into 3 risk groups: low, intermediate, and high. The scoring system deployed online as a web-based calculator can be accessed at https://kathavs.shinyapps.io/Mitracox_Kapadia/. In conclusion, MitraCox score is easy to calculate and predicts in-hospital mortality depending on length of stay in a dynamic manner.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Mortalidade Hospitalar , Valva Mitral/cirurgia , Hospitalização , Hospitais , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco
20.
JACC Heart Fail ; 11(8 Pt 2): 1070-1083, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37611989

RESUMO

Concomitant aortic stenosis (AS) in heart failure (HF) is associated with high rates of mortality and morbidity. Current guidelines recommend aortic valve replacement in patients with severe symptomatic AS and asymptomatic AS with left ventricular ejection fraction <50% and during other cardiac surgeries. Transcatheter aortic valve replacement (TAVR) has now allowed for the treatment of severe AS in previously inoperable or high-surgical-risk patients. Leveraging multimodality imaging techniques is increasingly recognized for reinforcing the rationale for intervening early, thus mitigating the risk of ongoing progression to advanced HF. There are increasing data in favor of TAVR in diverse clinical scenarios, particularly asymptomatic AS and moderate AS. Limited information is, however, available regarding the advantages of HF medical therapy before and after intervention. This review aims to comprehensively examine the phenotypes of AS in the context of HF progression, while exploring the evolving role of TAVR in specific populations.


Assuntos
Valvopatia Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência Cardíaca/cirurgia , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...